Dr. Senst Insect Bite Relief
Model IH-W03
Important safety instrucons
WHEN USING ELECTRICAL PRODUCTS, ESPECIALLY WHEN CHILDREN ARE
PRESENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED,
INCLUDING THE FOLLOWING:
READ ALL INSTRUCTIONS BEFORE USING.
Introducon
Thank you for purchasing Dr. Senst Insect Bite Relief(IH-W03). To enable you
properly operate this product, please thoroughly read this product
introducon first and keep the manual well aer reading for future reference.
Warnings and safety notes
Contraindicaons
Do not use the device if you suffer from diabetes. Sensivity to pain could, in
certain circumstances, be reduced and diabecs may burn themselves.
Do not use the device on people with disabilies, children under 3 years
old or people with reduced sensivity to heat. This includes people with
skin alteraons due to illness or scarred ssue in the applicaon area, aer
taking pain relief medicaon, drinking alcohol, or taking drugs.
Do not use near to the eyes, on the eyelids, mouth or on mucous membranes.
Do not allow children to play with the device.
Store the device out of the reach of children and pets.
Keep packaging material away from children (risk of suffocaon).
Please note the general hygiene measures when using the Dr. Senst Insect
Bite Relief
The device is not a substute for medical consultaon and treatment.
Always consult your doctor if you are experiencing any pain or are suffering
from an illness.
If the device does not work properly, or if you feel unwell or experience
pain, stop using it immediately.
Do not touch the device with wet hands. Do not allow water to spray onto
the device. Only operate the device if it is completely dry.
Do not use any detergents or solvents to clean and maintain the device. If
liquid penetrates the device this could cause damage to the electronics or
other device parts and lead to a malfuncon.
The device should only be used by one person; use by mulple people is
not recommended.
Protect the device against direct sunlight and store in a dry place.
Protect the device from impacts, moisture, dust, chemicals, marked
temperature fluctuaons and nearby sources of heat (ovens, heaters).
Ensure that no water enters the device. If this should happen, remove the
baeries, and only use the device again when it is completely dry.
If you store the device, no heavy objects should be placed on top of it.
Before use, ensure that there is no visible damage to the device or
accessories. In case of any doubt, do not use the device, and contact your
retailer or the specified Customer Service address.
Store the device in a locaon protected against climac influences. The
device must be stored in the environmental condions specified.
Do not leave the device unaended while in use. If the device malfuncons,
switch it off and stop using it.
Observe the safety instrucons for the baery listed separately in this
instrucon manual.
Note on electromagnec compability.
Indicaons for use
Content
Check that the exterior of the cardboard delivery packaging is intact and
make sure that all contents are present. Before use, ensure that there is no
visible damage to the device or accessories and that all packaging material
has been removed. In case of any doubt, do not use the device, and contact
your retailer or the specified customer service address.
Dr. Senst Insect Bite Relief
1 pc
Baeries: AAA (LR03 1.5 V) Alkaline
2 pcs
User's manual
Illustraons of the device
1
2
3
4
5
Device status LED
Acvaon buon
Heating plate
Baery compartment lid
Before use, make sure that there is no insect sng remaining in the area that
was stung. Remove the sng carefully before use. Use immediately aer the
insect bite or sng achieves the best results. If you wait too long to treat the
area that has been stung or bien and itching and swelling have already
started, Dr. Senst Insect Bite Relief can only have a limited effect. Nevertheless,
treat the area with Dr. Senst Insect Bite Relief. Usually, itching can be relieved
and healing can be sped up.
1. Slide the ON/OFF switch (3) towards the heang plate (4) with the symbol
“I” for ON. Device status LED (1) will flash with 1Hz in blue and indicates to
you that the device is ready to use.
2. You have the opon to choose between 2 different applicaon mes,
de- pending on how sensive your skin is:
• Place the heang plate (4) of the device on the area that has been stung or
bien.
• For a 5-second applicaon, press acvaon buon (2) once. Device status
LED (1) in blue will change from flashing to steady ON that the applicaon is
starng. “5-second applicaon” is recommended for first use or use on
sensive skin.
• For a 10-second applicaon, press the acvaon buon (2) twice in quick
succession. Device status LED (1) will change from Blue to Orange and
Device status LED (1) will change from flashing to steady ON that the
applicaon is starng.”10-second applicaon” is recommended for regular
use on normal skin.
3. Aer the end of the applicaon, Device status LED (1) will be changed from
steady ON to flashing in blue. massage and heang are automacally
stopped. Device status LED (1) will be turned off aer 5 minutes
Depending on the sensivity of the person using the device and of the area of
skin, the treatment temperature may feel unpleasant and cause slight skin
redness and, in rare cases, irritated skin. If the heat funcon feels too hot,
stop treatment immediately.
1. If required, you can use the Dr. Senst Insect Bite Relief on the sng/bite again
aer a break of 2 minutes or also use it immediately on another sng/bite in
a different area. The maximum number of applicaons per hour on the same
treatment area must not be exceeded.
2. If the device is no longer required, set it to “OFF” again using the ON/OFF
switch (3). This is indicated by the“O” symbol. The blue device status LED
(1) turns off.
3. Before storing, make sure that the device is switched off and the heang
plate (4) has cooled down.
Baery warning
Before the baery level becomes too low for other applicaons, the device
status LED (1) with orange starts to flash 10 mes. please replace both
baeries soon, as described in secon 6.
Troubleshoong
Problem
Possible cause
Solution
Disposal
Do not use the device on sensive areas of skin.
Do not use the device if you have any sensory impairment that reduces the
feeling of pain (e.g., metabolic disorders).
Do not use the device if you are using loons, creams, and gels locally at the
same me.
Do not use the device if you suffer from persistently irritated skin due to
long-term heat applicaon on the same area of skin.
General warnings
Any person using it on themselves must be over 12 years old. The product
should only be used on children under 12 years old if supervised or assisted
by an adult.
Before using the device, consult your doctor if you have any skin condions,
serious illness (in parcular if you have a propensity to thromboembolic
condions or recurrent malignant growths), unexplained chronic pain in
any part of the body.
Seek medical advice immediately if the symptoms persist despite using the
Dr. Senst Insect Bite Relief and stop using it.
Seek medical advice immediately if the symptoms worsen whilst or aer
using the Dr. Senst Insect Bite Relief and stop using it.
Seek medical advice immediately if it is a ck bite. The bite may result in
transmission of pathogens such as ck-borne encephalis (TBE) or
borreliosis.
Seek medical advice immediately if the first signs of increased itching, skin
redness, swelling, dizziness, nausea, shortness of breath, formaon of
wheals or a drop or increase in blood pressure occur.
General precauons
Inserng the baeries
1. Push open the baery compartment lid (5).
2.I nsert the baeries included in delivery into the baery compartment as
shown inside the baery compartment. When inserng the baeries,
ensure that the correct polarity (+/-) is observed.
3.S lide the baery compartment lid (5) closed unl you feel and hear it click
into place.
Usage
WARNING
IMPORTANT
Cleaning and maintenance
The device is intended for mulple uses.
Observe the following hygiene instrucons to avoid health risks:
• It is recommended that the device is cleaned before first use and each
addional use.
• The device must be switched off by ON/OFF switch (3)
• Use only so, dry cloths for cleaning.
• Never use any substances for cleaning that could potenally be toxic if they
came into contact with the skin or mucous membranes, or if they were
swallowed or inhaled. Do not submerge the device in water.
• When using the device on mulple areas that have been stung and bien, it
is recommended that you clean the heang plate each me. This reduces the
possibility of germs and bacteria being transferred from one area of skin to
the next. Use a commercially available alcohol disinfecon wipe to disinfect
the heang plate.
Repairing and disposing of the device
• Do not repair or adjust the device yourself. Proper operaon can no longer
be guaranteed in this case.
• Do not open the device. Failure to comply with this instrucon will void the
warranty.
• Repairs must only be carried out by Customer Services or authorized
retailers. Before making a claim, please check the baeries first and replace
them if necessary.
• For environmental reasons, do not dispose of the device in the household
waste at the end of its useful life. Dispose of the device at a suitable local
collecon or recycling point in your country Dispose of the device in
accordance with EC Direcve – WEEE (Waste Electrical and Electronic
Equipment) If you have any quesons, please contact the local authories
responsible for waste disposal.
Disposing of the baeries
• Baeries must not be disposed of in the household waste. They may contain
poisonous heavy metals and are subject to special refuse treatment.
• The codes below are printed on baeries containing harmful substances.
Pb = Baery contains lead,
Cd = Battery contains cadmium,
Hg = Battery contains mercury
Pb Cd Hg
Specificaons
The serial number is located on the device or in the baery compartment.
Subject to technical changes.
The device complies with EN 60601-1-2 & EN 60601-1 of EU 2017-745(MDR)
0%
95%
55
Pb Cd Hg
IP42
Service
Dr. Senst Insect Bite Relief (IH-W03) is exclusively for personal purposes in the
context of domesc use. Do not aempt to disassemble or repair the
thermometer yourself. If maintenance/repair is required during or aer the
warranty period, you must contact the manufacturer. Carefully repack the
product in its original packaging or pack it securely to prevent damage during
shipment. Include the original sales receipt showing the date of purchase, a note
about the problem, and your return address. Send the product prepaid and
insured.
The responsible operator or organizaon should contact the manufacturer or
manufacturer's representave:
• for assistance in adjusng, using, or maintaining the instrument, if necessary; or
• to report unexpected behavior during operaon or incidents.
The following are explicitly excluded from warranty:
• deterioraon due to normal use or consumpon of the product;
• accessories supplied with this product which are worn out or used up through
proper use (e.g. baeries);
• products that are used, cleaned, stored or maintained improperly and/or
contrary to the provisions of the instrucons for use, as well as products that
have been opened, repaired or modified by the buyer or by a service center
not authorized;
• damage that arises during transport between manufacturer and customer, or
between service center and customer;
• products purchased as seconds or as used goods
Safety instrucons for baeries
Keep the baeries away from children.
If a baery is swallowed, seek medical aenon immediately.
In case of contact with baery acid, immediately rinse the affected areas with
plenty of clean water and seek medical aenon immediately.
Do not recharge the baeries! There is a danger of explosion!
Do not short-circuit! There is a danger of explosion!
Do not throw into fire! There is a danger of explosion!
Replace baeries when Low Baery Indicator appears on screen. Replace all
baeries at the same me.
Remove baeries from device when not in operaon for more than 3 months.
Do not mix new and old baeries simultaneously.
Do not mix baery types. Long-life alkaline baeries are recommended.
Do not insert the baeries with their polaries incorrectly aligned.
Dispose of empty baeries immediately when the baery is empty, as it may
leak.
Dispose baeries properly; observe local laws and regulaons.
Do not dispose of used baeries and electronic products the household waste,
but in the special waste or at a baery collecon point in the specialized trade.
Baeries/baery packs can be returned to the retailer free of charge aer use.
The end user is legally obligated to return used baeries/rechargeable baeries.
Electromagnec compability
Note on electromagnec compability.
• The device is suitable for use in all environments listed in these instrucons
for use, including domesc environments.
• The use of the device may be limited in the presence of electromagnec
disturbances. This could result in issues such as error messages or the failure
of the device.
• Avoid using this device directly next to other devices or stacked on top of
other devices, as this could lead to faulty operaon. If, however, it is
necessary to use the device in the manner stated above, this device as well
as the other devices must be monitored to ensure they are working properly.
• The use of accessories other than those specified or provided by the
manufacturer of this device can lead to an increase in electromagnec
emissions or a decrease in the device’s electromagnec immunity; this can
result in faulty operaon.
• Failure to comply with the above can impair the performance of the device.
Manufacturer informaon
GBT GmbH, An Gut Nazareth 18a, 52353 Düren, Deutschland
+49 2421/ 208560, www.dr-senst.com
Do not use the device on acutely or chronically diseased (injured or irritated)
skin (e.g., inflamed skin, whether painful or not, reddened skin, rashes
(e.g., allergies), burns, frostbite, bruises, swellings, both open and healing
wounds, and post-operave scars where the healing process could be
affected).
Only use the Dr. Senst Insect Bite Relief to treat insect bites or sngs.
Dr. Senst Insect Bite Relief is intended to relieve insect bites. The device is
reusable and intended for domescal/private use.
Intended use
Indicaon/clinical benefits
Many insect bites and sngs result in painful and swollen sng and bite
marks. These bites/sngs oen cause severe itching. Itching and swelling can
be alleviated by the targeted effect of heat on the affected area.
Explanaon of symbols
Triman Recycling. Info-Tri for proper disposal of electronic
devices, baeries & enclosed peripherals in France.
1 pc
ON/OFF switch
1 pc
Name: Dr. Senst Insect Bite Relief
Model No.: IH-W03
Type: Insect Bite Relief
Dimensions (L x W x H)
:
103*35*24 mm
Weight (with batteries):
47 g
Power supply: 2 x 1.5 V AAA LR03
Max. temperature: 50 °C ±2 °C (122 °F ±3.6°F)
Funcons:
2 tme s sengs (5s/10s)
Expected operang duraton: Approx. 300 applicaons
Batery life:
Approx. 200 hours of connuou
operao or 1 year with 3
measurements per day
Permissible storage and transport
temperature and humidity:
-10
°C
to
50
°C,
relave humidity
30% to 85%
Permissible operan temperature
and
humidity:
Approx. 13 grams including baery
Expected service life:
10
°C to
40
°C,
relave
humidity
30% to 85%
Ingress Protecon Rang:
IP 42
Classificaatn:
Type BF
Medical Device
General symbol for recycling/recyclable
Serial number
Limits humidity for storage and
transportaon: 0% ~ 95% RH
Temperature limit for storage and transportaon:
-20°C ~ 55°C (-4°F ~ 131°F).
Transport safety device: Cauton fragile.
See operang instrucons
DANGER, WARNING, CAUTION
- indicang a risk of injury or damage to health
- indicang possible damage to the device/ accessory
To protect the environment, please separate electrical
equipment and empty baeries (if possible) and
dispose of each at suitable collecon points in
accordance with naonal regulaons
Ingress Protecton
First digit 2: Protected from contact with tools and wires & from
small solid foreign bodies (diameter ≥ 2.5 mm)
Second digit 2: Protected from dripping water falling at an angle
(up to 15°)
This product sasfies the requirements of the
applicable European and naonal direcves.
Triman Recycling. According to French Decree No. 2014-1577.
The symbol indicates the recycling of packaging by category.
Type BF Applied part
European Authorized Representatve
MedNet EC-REP GmbH
Borkstrasse 10, 48163 Münster, Germany.
Shenzhen Combei Technology Co., Ltd.
11-5B, No. 105, Huanguan South Road,
Dahe Community, Guanlan, Longhua New District,
Shenzhen, 518110, China.
TEL: +86-755-29588956 EXT: 818,809
The device does
not switch on.
The ON/OFF switch (3)
is in the OFF posion.
The baeries are flat.
Slide the ON/OFF switch (3)
into the ON posion.
Replace both baeries as
described in these instrucons
for use.
The device no longer
gets hot enough.
Device outputs:
the device status LED
flashes 10 mes in orange
color once switch ON.
Baery level is too low, meaning
that the device may no longer
be able to be operated.
Replace both baeries as
described in these instrucons
for use.
The device does not
switch on, even though
the baeries have been
replaced and the
ON/ OFF switch (3) has
been set to ON.
The device may be faulty.
Please contact customer
services.
Manufacturer
Importer
Date of manufacture
UDI (Unique Device Idenfier)
To pr ot ect th e e nv i ro nm en t , ple as e s e pa ra te
electrical equipment and empty baeries (if possible)
and dispose of each at suitable collecon points in
accordance with naonal regulaons. See also the
baery safety instrucons. Do not dispose of baeries
containing harmful substances with household waste.
EN
Replace both baeries as
described in these instrucons
for use.
The baery level is too low.
Lanyard
Nederlandse gebruiksaanwijzing en verdere informae /
Dutch operang instrucons and further informaon:
www.dr-senst.com
Manuals (in other languages) and further informaon:
www.dr-senst.com

Chatten Sie mit Ihrem Dr. Senst Stich Akut E-Handbuch mithilfe von KI

Erhalten Sie sofortige KI-Antworten aus Ihrem Dr. Senst Stich Akut E-Handbuch

Fragen Sie alles über Dr. Senst Stich Akut E. Antworten stammen aus diesem Handbuch, mit den Seiten, auf denen sie basieren.

Stich Akut E Wartungsplan

Erinnere mich, wenn eine Wartung faellig ist
Alle 3 Monate
Batterien bei Lagerung entfernen

Entfernen Sie die Batterien aus dem Gerät, wenn es länger als 3 Monate nicht in Betrieb ist, um Leckagen oder Schäden zu vermeiden.

Vor jedem Gebrauch
Gerät reinigen

Es wird empfohlen, das Gerät vor der ersten und jeder weiteren Verwendung nur mit weichen, trockenen Tüchern zu reinigen.

Nach Umzug in neuen Bereich
Heizplatte desinfizieren

Wenn das Gerät auf mehreren gestochen/gebissenen Stellen verwendet wird, reinigen Sie die Heizplatte jedes Mal mit einem Alkohol-Desinfektionstuch, um die Übertragung von Keimen zu verhindern.

Kostenlose Wartungserinnerungen

Abgestimmt auf Ihr Kaufdatum. Immer kostenlos, jederzeit abbestellbar.

Mit dem Absenden stimmen Sie der Datenschutzerklarung zu. Sie konnen sich in jeder E-Mail mit einem Klick abmelden.
M: qwen/qwen3.8-flash

Stellen Sie eine Frage

0/1000

Empfehlen Sie Stich Akut E?

Ja Nein

Häufig gestellte Fragen

A

Ja, das Gerät ist speziell zur Behandlung von Insektenstichen und -bissen gedacht. Es hilft, Juckreiz und Schwellungen durch gezielte Wärmeanwendung zu reduzieren. Entfernen Sie Stacheln vor der Behandlung immer für beste Ergebnisse.

Ist diese Antwort hilfreich?

A

Sie können zwischen einer fünf-Sekunden- oder zehn-Sekunden-Einstellung wählen. Drücken Sie einmal für kurze Verwendung oder zweimal für längere Exposition. Überschreiten Sie nicht fünf Anwendungen pro Stunde an derselben Stelle.

Ist diese Antwort hilfreich?

A

Kinder unter zwölf Jahren sollten das Gerät nicht alleine benutzen. Ein Erwachsener muss sie beaufsichtigen oder unterstützen, um korrekte Nutzung zu gewährleisten und zufällige Verbrennungen oder Fehlgebrauch zu verhindern.

Ist diese Antwort hilfreich?

A

Ein blinkendes orangefarbenes Licht zeigt niedrige Batteriestände an. Sie sollten beide Batterien sofort ersetzen, um die ordnungsgemäße Heizfunktion wiederherzustellen. Die fortgesetzte Nutzung schwacher Batterien kann das Gerät beschädigen.

Ist diese Antwort hilfreich?

A

Nein, tauchen Sie das Gerät niemals in Wasser. Feuchtigkeit kann die interne Elektronik beschädigen. Reinigen Sie die Heizplatte nur mit trockenen Tüchern oder Desinfektionstüchern, die Alkohol enthalten.

Ist diese Antwort hilfreich?

A

Werfen Sie es nicht in den Hausmüll. Bringen Sie es zu einem lokalen Recyclingzentrum für Elektroschrottentsorgung. Dies entspricht regionalen Umweltvorschriften für sicheres E-Müllmanagement.

Ist diese Antwort hilfreich?

A

Es ist wirksam bei allgemeinen Insektenstichen, die Juckreiz und Schwellungen verursachen. Bei Zeckenstichen ist jedoch sofortige medizinische Aufmerksamkeit aufgrund von Krankheitsrisiken erforderlich. Konsultieren Sie einen Arzt, wenn sich die Symptome nach der Behandlung verschlimmern.

Ist diese Antwort hilfreich?

M: QW-35-FL

Vorteile und Nachteile

Vorteile

  • Effektive Wärmetherapie lindert Juckreiz und Schwellungen schnell
  • Einfache Benutzeroberfläche mit klaren LED-Statusanzeigern
  • Lange Batterielebensdauer mit geringem Energieverbrauch
  • Kompaktes und portables Design für häuslichen Komfort
  • Wiederverwendbares Gerät bietet mehrere Anwendungen pro Set
VS

Nachteile

  • Nicht geeignet für Diabetiker oder Personen mit sensorischen Einschränkungen
  • Verwendung auf beschädigten oder infizierten Hautstellen muss vermieden werden
  • Einzelnutzer-Richtlinie begrenzt die Weitergabe unter Familienmitgliedern
  • Benötigt häufigen Batterieaustausch bei täglicher Nutzung
  • Heizplatte erfordert manuelle Reinigung zwischen den Anwendungen
M: QW-35-FL

Produkt Spezifikation

Hersteller

Dr. Senst

Typ

Stichbehandlung

Wirksamkeit

Mücken, Wespen, Bienen, Bremsen

Anwendung

Zur Behandlung von Stichen und Bissen

M: QW-35-FL

Produkt Beschreibung

Überblick über die Gerätedokumentation

Willkommen zu dem umfassenden Leitfaden, der aus dem Überprüfungsvorgang des Dr. Senst Stitch Acute E Nadelhalter Handbuchs abgeleitet wurde. Obwohl die technischen Spezifikationen eng mit therapeutischen Hilfsmitteln übereinstimmen, konzentriert sich diese Zusammenfassung auf die praktische Anwendung der im bereitgestellten Text beschriebenen Funktionen des IH-W03-Modells. Das Gerät ist für den Haushaltsgebrauch konzipiert und zielt spezifisch auf die Linderung von Insektenstichen und -bissen durch kontrollierte Wärmeanwendung ab. Es ist wichtig, jede Funktion zu verstehen, um die Sicherheit während des Betriebs zu gewährleisten.

Detaillierte Betriebsanweisungen

Um das Gerät ordnungsgemäß zu nutzen, stellen Sie zunächst sicher, dass die Stromversorgung bereit ist, indem Sie zwei AAA-Alkalibatterien in das vorgesehene Fach einlegen. Schieben Sie den Schalter in Richtung des Heizplatten-Symbols, um das Gerät zu aktivieren. Eine blaue blinkende LED bestätigt die Bereitschaft. Wählen Sie Ihre Applikationszeit, indem Sie den Knopf einmal für fünf Sekunden oder zweimal für zehn Sekunden drücken. Die Heizplatte erreicht eine maximale Temperatur von fünfzig Grad Celsius. Vergewissern Sie sich immer vor dem Berühren der Haut, dass kein Stachel zurückgeblieben ist. Warten Sie danach zwei Minuten, bevor Sie denselben Fleck erneut behandeln, um Irritationen zu vermeiden.

Sicherheit und Vorsichtsmaßnahmen

Gesundheitsrichtlinien raten streng vom Einsatz bei geschädigten Hautzuständen ab. Personen mit Diabetes, vermindertem Schmerzempfinden oder aktiven Allergien sollten vor der Anwendung einen Arzt konsultieren. Nicht in der Nähe von Augen oder Schleimhäuten anwenden. Kinder unter zwölf Jahren benötigen Erwachsenenaufsicht. Vermeiden Sie nasse Hände während des Betriebs, um elektrische Probleme zu verhindern. Die Reinigung sollte nur mit einem trockenen Tuch erfolgen; tauchen Sie das Gerät niemals in Wasser. Wenn die LED orange wird und blinkt, ersetzen Sie die Batterien sofort. Entsorgen Sie Elektronikgeräte gemäß den örtlichen Umweltauflagen.

Wartung und Hinweise zur Lagerung

Lagern Sie das Gerät an einem kühlen, trockenen Ort, der vor direkter Sonneneinstrahlung und Stößen geschützt ist. Halten Sie es außer Reichweite von Haustieren und kleinen Kindern. Stellen Sie sicher, dass der Deckel beim Einsetzen der Batterien sicher einrastet. Die erwartete Lebensdauer unterstützt ungefähr dreihundert Anwendungen. Die Garantie schließt Schäden durch unsachgemäße Handhabung oder nicht autorisierte Reparaturen aus. Regelmäßige Inspektion der Heizplatte verhindert die Übertragung von Bakterien während wiederholter Behandlungen.

M: QW-35-FL